Cleaning rules and problem solving of glass fiber reinforced plastic cooling tower
Release Time:2021-07-15
Glass fiber reinforced plastic cooling tower is a new type of material cooling tower, for glass fiber reinforced plastic cooling tower not only to ensure that the tower is clean, the tower surface long-term exposure to the air cleaning work should be done in place, let's take a look at the glass fiber reinforced plastic surface common stains should be how to clean it:
1. The rust caused by dirt on the surface of the glass fiber reinforced plastic cooling tower can be washed with 10% nitric acid or abrasive detergent, and can also be washed with special washing drugs.
2. If there is dust on the surface of the glass fiber reinforced plastic cooling tower and it is easy to remove dirt, it can be washed with soap, weak detergent or warm water.
3, glass steel cooling tower surface trademark, film, with warm water, weak detergent to wash, binder composition, the use of alcohol or organic solvents (ether, benzene) scrub.
4. The grease, oil, and lubricating oil pollution on the surface of the FRP cooling tower should be wiped clean with a soft cloth, and then cleaned with a neutral detergent or ammonia solution or a special washing cooling tower agent.
5, glass fiber reinforced plastic cooling tower surface bleach and a variety of acid adhesion, immediately rinse with water, and then use ammonia solution or neutral carbonated soda solution immersion, washing with neutral detergent or warm water.
6. There are rainbow patterns on the surface of the glass fiber reinforced plastic cooling tower, which are caused by excessive use of detergent or oil. When washing, it can be washed away with warm water neutral detergent.
FRP cooling tower floating water phenomenon has a great impact on the safety of the cooling tower itself and the safety of the surrounding equipment environment. Since the cooling tower floating water phenomenon has such great harm, we must prevent and deal with the cooling tower floating water phenomenon in advance. Let's see how to prevent and solve it:
1. The square cross-flow cooling tower of the hydraulic fan adopts large and wide-leaf fans. Under the condition of a certain air volume, increasing the windward surface can reduce the fan speed, thereby reducing the speed of water droplets and reducing the drifting of the air duct.
2. After the packing of the cooling tower is assembled, the air inlet surface is a honeycomb-shaped deflector, which has a good uniform air distribution effect, improves and stabilizes the heat exchange intensity of water and gas, and the air inlet end is inclined at an angle of 30 degrees to the tower, so that the air flow can be introduced, but the water droplets cannot be splashed out, effectively reducing the loss of floating water.
3, increase the fan blade width, reduce the fan speed, so as to alleviate the cooling tower floating water loss.
4. It is necessary to increase the natural gravity water distribution nozzle and increase the water retaining part between the filler and the water distribution pool, so as to improve the water distribution mode of the cooling tower.
5. Replace the head and clean the sprinkler pipe. If the pressure of the water pump is too high, replace the appropriate water pump directly.
6. Renovate the water-drenching filler of the cooling tower, and increase the water-collecting structure of the inlet and outlet parts of the filler on the basis of the original filler, so as to make the filler water vapor return backward after folding to the maximum extent and reduce the amount of water taken away by the fan.
The inlet and outlet water temperatures of FRP cooling towers are strictly regulated and have been set in advance. However, some customers have reported that the water temperature of the cooling tower suddenly exceeded the specified temperature abnormally. What is the reason? Let's listen to how experts analyze this failure: the water in the tower is not smooth when circulating, the circulating water in the tower is too much or too little, and the air volume of the fan is insufficient, in the process of circulation, the phenomenon of secondary circulation of hot gas occurs, among which the heat sink and the water pipe have an important influence on the temperature, which should be checked one by one and handled in a timely manner.
How can we solve this problem when the cooling tower suddenly appears during work? First, check the water volume in the tower to see if it meets the normal standard. Too much or too little water volume will cause the water temperature to rise. Second, check the circulation system to see if there is any hot air circulating. Finally, check the air volume of the fan. Insufficient or uneven air volume and blockage of the air outlet will cause the water temperature to rise.
Shandong Xingheng Environmental Technology Group Co., Ltd. is located in Luquantun Development Zone, Dezhou, Shandong Province, the hometown of glass fiber reinforced plastic in China. The company has three-level qualification for construction mechanical and electrical installation engineering, three-level qualification for environmental protection engineering, and safety production license. It is the first in the industry to pass ISO9001 quality management system certification, ISO14001 environmental management system certification, OHSAS18001 occupational health management system certification, an axial fan invention patent, a fan utility model patent, EIA, three at the same time and other procedures are complete.
Service hotline:
400-018-2011
Address: Development Zone, Luquantun Town, Wucheng County, Dezhou City, Shandong Province
Mobile Website
Links:
Xingheng Environmental Technology Group Co., Ltd.
Xingheng Environmental Technology Group Co., Ltd.
Xing Heng Environmental Technology Co., Ltd
Xingheng Environmental Technology Group
Xingheng Environmental Technology Group 2
Xingheng Environmental Technology Group Co., Ltd.