Glass fiber reinforced plastic cooling tower is the "darling" of many industries, that is to say, our glass fiber reinforced plastic cooling tower is needed in many industries. Today, Xiao Bian would like to introduce to you some ideas about the use of glass fiber reinforced plastic cooling tower in winter.
I don't know if you know that cooling towers use coolant when they work, but these liquids are very easy to freeze in winter when the temperature is low, especially at the air inlet. However, what harm will FRP cooling towers have if they freeze? With this problem, we continue to look below:.
Freezing at the air inlet will affect the air inlet volume and thus the cooling effect. In addition, experts say that freezing at the filling area will also affect the normal operation of the equipment. Therefore, we must pay attention to protecting these key points that are easy to freeze to reduce equipment damage caused by freezing cooling tower.
I believe everyone is already very familiar with this kind of mechanical equipment. But Xiaobian is still going to talk about FRP cooling towers today. Today, I want to tell you about the mistakes that often occur in the operation of FRP cooling towers. We all know that any mistake will definitely affect FRP cooling towers. Therefore, we must let everyone know about this problem.
OK, now let's enter the theme: first of all, we need to know that temperature control is very critical during its operation. although its main function is cooling, it will also generate a certain amount of heat in the middle, so we must control this problem because if we ignore the temperature, it will always rise, which will directly affect the cooling effect of the cooling tower, once the temperature is not controlled in time at the beginning, the cost of power will increase if we want to maintain the low temperature at the later stage, so we must control it in time in case of abnormal temperature.
FRP cooling tower should always pay attention to the operation of the equipment to see if there is any abnormality. Fortunately, the solution should be found and determined in the first place when there is a failure. In the work of FRP cooling tower, the following aspects should be paid attention:.
1. Check whether the fan is operating normally. After the fan is turned on for 30 minutes, check that the heating state of the oil bath bearing seat is normal operation at 60-80 ℃.
2. Check whether the windmill has abnormal friction sound, and feel that the windmill shell has no obvious vibration. The glass fiber reinforced plastic cooling tower needs to be checked during normal operation.
3. Check whether the fan is operating normally. After the cooling tower fan is turned on for 30 minutes, check that the heating state of the oil bath bearing seat is normal operation at 60-80 ℃.
4. Check whether the windmill has abnormal friction sound, and the windmill shell has no obvious vibration.
5. Check whether the circulating pump is operating normally, whether it is leaking, and whether the nozzle spray water is normal.
6. Check whether each valve is in the correct switch position.
7. Check the working condition of the water pump, regularly check and clean the sediment in the nozzle head.
8. Check whether the dosing pump is working normally, and often remove impurities in the medicine box to prevent blocking the suction port.
9. It is strictly forbidden to pour high-concentration medicine into the water tank in large doses. This abnormal behavior will cause the collapse of the filler bracket in the tower body and serious damage to the water tank.
Always ensure the normal operation of the glass steel cooling tower will not affect the work efficiency.
Shandong Xingheng Environmental Technology Group Co., Ltd. is located in Luquantun Development Zone, Dezhou, Shandong Province, the hometown of glass fiber reinforced plastic in China. The company has three-level qualification for construction mechanical and electrical installation engineering, three-level qualification for environmental protection engineering, and safety production license. It is the first in the industry to pass ISO9001 quality management system certification, ISO14001 environmental management system certification, OHSAS18001 occupational health management system certification, an axial fan invention patent, a fan utility model patent, EIA, three at the same time and other procedures are complete.
Service hotline:
400-018-2011
Address: Development Zone, Luquantun Town, Wucheng County, Dezhou City, Shandong Province
Mobile Website
Links:
Xingheng Environmental Technology Group Co., Ltd.
Xingheng Environmental Technology Group Co., Ltd.
Xing Heng Environmental Technology Co., Ltd
Xingheng Environmental Technology Group
Xingheng Environmental Technology Group 2
Xingheng Environmental Technology Group Co., Ltd.