Enterprise Information

FRP energy-saving cooling tower and maintenance attention

Release time:

2021/07/20 08:13

The load on the foundation of the cooling tower is shown in the "foundation buried plate and load table". the inlet and outlet pipes of the cooling tower rotate at 90, 180 and 270 degrees. the water distribution system is designed according to the nominal cooling tower water volume. if the difference between the actual water volume and the nominal water volume is more than 15%, it should be stated when ordering that the inlet water temperature of the cooling tower is not more than 60 ℃, and if it exceeds 60 ℃, it should be stated when ordering.

FRP cooling tower maintenance skills and heat dissipation process

Release time:

2021/07/20 08:12

When the FRP cooling tower is completed or installed and put into operation, the design unit or manufacturer shall provide all the characteristic data of the cooling tower: including thermal characteristics, resistance characteristics, water load, heat load, ambient temperature (dry and wet bulb temperature), cooling range, air flow rate, power consumption, wind blowing loss, evaporated water quantity, supplementary water quantity, concentration ratio, fan power consumption, water pressure entering the tower, etc, the relevant departments in charge of the user unit shall make operation records according to all the characteristic data and contents of the cooling tower provided by the above design unit or manufacturer.

Cooling tower fan energy-saving methods and maintenance skills

Release time:

2021/07/20 08:07

Cooling tower fans are the core equipment of circulating water system. In terms of circulating water equipment management, cooling tower fans account for a large proportion in terms of equipment quantity, maintenance workload, power consumption, etc. The number of fans accounts for 57% of the total equipment in the workshop, maintenance time accounts for 60% of the total, and power consumption accounts for 22% of the total. How to improve the energy saving and consumption reduction efficiency of cooling tower fans and ensure the long-term operation of equipment, the following is a brief talk about the main methods and measures

Industrial glass steel cooling tower maintenance and cooling attention

Release time:

2021/07/20 08:01

Industrial glass fiber reinforced plastic cooling tower is the most common refrigeration equipment, which mainly refers to the cooling water and air direct contact between cold and heat exchange equipment, it needs to be composed of cooling tower fan, cooling tower packing, water system, tower body, water tray and other parts, in order to better apply this equipment, need to be maintained.

Material Requirements and Structural Characteristics of FRP Cooling Tower

Release time:

2021/07/19 17:25

The glass fiber reinforced plastic cooling tower has good corrosion resistance, heat resistance and other aspects due to the material relationship. However, one drawback is that the glass fiber reinforced plastic cooling tower has good rigidity but great brittleness. If there is a little accident in storage or operation, the steel tank is prone to rupture. Therefore, we should pay special attention to the storage and operation during work.

Causes of Foam Out of Cooling Tower and Air Volume Setting

Release time:

2021/07/15 10:20

Some customers in the use of glass fiber reinforced plastic cooling tower in the process of bubble phenomenon, cooling tower foam is certainly not normal, then what is the cause of glass fiber reinforced plastic cooling tower who appear this phenomenon.