Enterprise Information

Installation and structure of fan coil

Release time:

2021/07/20 11:08

1. The installation location of the air-conditioning host should be convenient for maintenance and does not affect its use function, especially pay attention to heat dissipation. When there are multiple hosts in the computer room, all hosts must take over the direction and operating surface in the same direction.

Use and control principle of horizontal fan coil

Release time:

2021/07/20 11:06

The main control parameters of horizontal concealed fan coil unit are rated air volume, outlet static pressure, input power, rated cooling capacity, rated heat supply, noise, water resistance, etc. For the fan coil unit of double-pipe water system (suitable for air conditioning system that only converts heating or cooling according to season or air conditioning area), only one set of coil units are configured, and both heating and cooling in winter and summer are equipped, for fan coil units of four-pipe water system (applicable to air conditioning systems with frequent heating/cooling conversion), a combined type of heating and cooling coils shall be configured.

Selection and parameters of a full set of fan coil

Release time:

2021/07/20 11:02

In the selection of fan coil refrigeration unit, is the design of the preheating load and unit sensible heat load matching, in most cases, the coil has enough latent heat capacity, can meet the design needs, such as the use of outdoor air is the corresponding repair.

Classification and Design Selection of Fan Coil

Release time:

2021/07/20 11:00

The types of fan coil units include: horizontal concealed fan coil units (with return air box), horizontal concealed fan coil units (without return air box), horizontal concealed fan coil units, vertical concealed fan coil units, vertical concealed fan coil units, card-type two-outlet fan coil units, card-type four-outlet fan coil units and wall-mounted fan coil units.

Selection and Installation of Fan Coil Unit

Release time:

2021/07/20 10:57

According to the use requirements and building conditions, select the type of fan coil and system layout, determine the fresh air supply mode and water pipe system type.

Little knowledge and principle of fan coil

Release time:

2021/07/20 10:51

Coil system components: fan coil, inlet and return water valve, Y-type filter, solenoid valve/water valve, control panel, return air duct and tuyere, heat preservation, fresh air duct, water pipe and metal hose.